U600 Series Ultrasonic Flaw Detector
|
||||
Standard number
|
TSG R0004-2009 EN12668-1:2000
|
|||
Product Description
|
IWIN-U600
|
IWIN-610
|
IWIN-620
|
IWIN-630
|
Working principle
|
Ultrasonic
|
Ultrasonic
|
Ultrasonic
|
Ultrasonic
|
Working frequency
|
(0.2~20)MHz
|
(0.5~20)MHz
|
(0.5~20)MHz
|
(0.5~20)MHz
|
Pulse Width
|
Square wave width 30~1000ns adjustable, step 0.1ns
|
Square wave width 30~1000ns adjustable, step 0.1ns
|
Square wave width 30~1000ns adjustable, step 0.1ns
|
Square wave width 30~1000ns adjustable, step 0.1ns
|
Detection range
|
0~14000 (Steel longitudinal wave)mm
|
0~14000 (Steel longitudinal wave)mm
|
0~14000 (Steel longitudinal wave)mm
|
0~14000 (Steel longitudinal wave)mm
|
Pulse shift
|
-45~1000(steel longitudinal wave)mm
|
-45~1000(steel longitudinal wave)mm
|
-45~1000(steel longitudinal wave)mm
|
-45~1000(steel longitudinal wave)mm
|
Material sound velocity
|
300~15000m/s
|
300~15000m/s
|
300~15000m/s
|
300~15000m/s
|
Detection method
|
Negative wave, positive wave, two-way wave, filter, RF wave
|
Negative wave, positive wave, two-way wave, filter, RF wave
|
Negative wave, positive wave, two-way wave, filter, RF wave
|
Negative wave, positive wave, two-way wave, filter, RF wave
|
Gain adjustment
|
0~110dB: 0.1/1/2/6 step adjustment
|
0~110dB: 0.1/1/2/6 step adjustment
|
0~110dB: 0.1/1/2/6 step adjustment
|
0~110dB: 0.1/1/2/6 step adjustment
|
Thickness measurement function
|
non
|
non
|
Normal mode 0.75-300mm, penetration coating 2-150mm
|
Normal mode 0.75-300mm, penetration coating 2-150mm
|
WIFI/HDMI/digital filtering wave
|
non
|
non
|
non
|
Mobile phone connection/HD projection/digital filtering
|
Sluice gate
|
Incoming gate, loss gate; single gate reading, double gate reading
|
Incoming gate, loss gate; single gate reading, double gate reading
|
Incoming gate, loss gate; single gate reading, double gate reading
|
Incoming gate, loss gate; single gate reading, double gate reading
|
DAC,AVG Function
|
DAC curve,AVG curve
|
DAC curve,AVG curve
|
DAC curve,AVG curve
|
DAC curve,AVG curve
|
Attenuator error
|
Every 12dB+-1dB
|
Every 12dB+-1dB
|
Every 12dB+-1dB
|
Every 12dB+-1dB
|
Vertical linearity error
|
≤3%
|
≤3%
|
≤3%
|
≤3%
|
Horizontal linearity error
|
≤0.5%
|
≤0.5%
|
≤0.5%
|
≤0.5%
|
Dynamic Range
|
≥30dB
|
≥30dB
|
≥30dB
|
≥30dB
|
Sensitivity margin
|
≥65dB (2.5Z20N Probe)
|
≥65dB (2.5Z20N Probe)
|
≥65dB (2.5Z20N Probe)
|
≥65dB (2.5Z20N Probe)
|
Far zone resolution
|
≥26dB
|
≥26dB
|
≥26dB
|
≥26dB
|
Electrical noise level
|
≤10(1~4MHz)%
|
≤10(1~4MHz)%
|
≤10(1~4MHz)%
|
≤10(1~4MHz)%
|
Equivalent input noise
|
<80x10-9V/√Hz
|
<80x10-9V/√Hz
|
<80x10-9V/√Hz
|
<80x10-9V/√Hz
|
Pulse repetition frequency
|
20~1000Hz,Stepping 25V
|
20~1000Hz,Stepping 25V
|
20~1000Hz,Stepping 25V
|
20~1000Hz,Stepping 25V
|
Pulse voltage
|
25~400V can adjust,step 25V
|
25~400V can adjust,step 25V
|
25~400V can adjust,step 25V
|
25~400V can adjust,step 25V
|
Thin plate resolution
|
≤3(5C10N Probe)mm
|
≤3(5C10N Probe)mm
|
≤3(5C10N Probe)mm
|
≤3(5C10N Probe)mm
|
AWS D1.1/D1.5
|
The AWS D1.1/D1.5 of the American Welding Association (AWS) calculates the weld level of steel structures and bridges
|
Support
|
Support
|
Support
|
Working voltage
|
12V (Battery,DC)
|
12V (Battery,DC)
|
12V (Battery,DC)
|
12V (Battery,DC)
|
Appearance size
|
180x130x40mm (Height*Width*Depth)
|
180x130x40mm (Height*Width*Depth)
|
180x130x40mm (Height*Width*Depth)
|
180x130x40mm (Height*Width*Depth)
|
Storage
|
Storage card
|
Storage card
|
Storage card
|
Storage card
|
Probe damping
|
100Ω, 200Ω, 400Ω optional
|
|||
Real-time sampling of hardware
|
High resolution 10-bit AD converter with sampling speed of 160MHz and high waveform fidelity
|
|||
Detection method
|
Positive half wave, negative half wave, full wave, radio frequency detection
|
|||
Filter band
|
(0.2~20)MHz, fully automatic matching according to probe frequency, no need to set manually
|
|||
Communication Interface
|
USB2.0 high speed communication transmission interface
|
|||
Ambient temperature and humidity
|
Temperature: (-10~50) °C Humidity: (20~95)%RH
|